PHS-98108 tester family ATC Pen PH meter

PHS-98108 tester family ATC Pen PH meter

  • PHS-98108 tester family ATC Pen PH meter
PHS-98108 tester family ATC Pen PH meter
Datos del producto:
Lugar de origen: Porcelana
Número de modelo: PHS-98108
Pago y Envío Términos:
Cantidad de orden mínima: 1 unidad de probador de PHS-98108 familia ATC Pen medidor de PH hanna
Precio: USD1 of PHS-98108 tester family ATC Pen PH meter hanna
Detalles de empaquetado: 100 piezas/caja de cartón de hanna PHS-98108 probador familia ATC pluma medidor de PH
Tiempo de entrega: 10 días del medidor de PH ATC Pen de la familia de probadores hanna PHS-98108
Condiciones de pago: TT de la familia de probadores PHS-98108 ATC Pen medidor de PH hanna
Capacidad de la fuente: 5000000 Uds. De probador de PHS-98108 familia ATC Pen medidor de PH hanna
Contacto
Descripción detallada del producto

PHS-98108 tester family ATC Pen PH meter

 

SPECIFICATIONS

 

Technical data:

Measuring range: 0.00~14.00pH

Resolution: 0.1pH

Accuracy: ±0.1pH or 0.05pH

Calibration: manual, 2 points

ATC:   5-60 

Power: 4×1.5v alkaline (AG13)

Auto shut-off: Approx. 4minutes

Dimension: 175×41×23mm

Weight: 90g

PHS-98108 tester family ATC Pen PH meter 0

OPERATION

• Remove the protective cap. Don't be worry if white crystals appear around the probe head. This is normal with pH electrodes and they dissolve when rinsed with water.

• Turn the meter on by sliding switch on the top.

• Immerse into solution up to the max immersion level.

• Stir gently and wait until the display stabilizes.

• After use, switch off pH meter, use the water clean the electrode and replace the protective cap.

• Large fluctuations in readings could be due to lack of calibration, dry electrode or rundown batteries.

PHS-98108 tester family ATC Pen PH meter 1

 

PHS-98108 tester family ATC Pen PH meter 2  PHS-98108 tester family ATC Pen PH meter 3

 

PHS-98108 tester family ATC Pen PH meter 4

PHS-98108 tester family ATC Pen PH meter 5

CALIBRATION

• Immerse the tester up to the maximum immersion level in pH 6.86 buffer solution

• Allow the reading to stabilize and using a small screwdriver adjust the calibration trimmer to read 6.86

Calibration is now complete.

ALWAYS USE FRESH BUFFERS FOR CALIBRATION.

 

BATTERY REPLACEMENT

When the meter cannot be switched on or the display fades, pull out the battery compartment and replace all three 1.5V batteries, while paying attention to their polarity. Batteries should only be replaced in a safe area using the battery type specified in  instruction manual.(1.5 Alklaine or AG13)

PHS-98108 tester family ATC Pen PH meter 6

HANNA HI98108 pHep PEN PH meter PH tester