Inicio ProductosPen PH meter, ORP meter, TDS meter, Conductivity meter

PH-108 PH-009II portable Pen PH tester meter with ATC

PH-108 PH-009II portable Pen PH tester meter with ATC

  • PH-108 PH-009II portable Pen PH tester meter with ATC
PH-108 PH-009II portable Pen PH tester meter with ATC
Datos del producto:
Lugar de origen: Porcelana
Número de modelo: PH-108, PH-009II
Pago y Envío Términos:
Cantidad de orden mínima: 1 unidad de medidor de prueba de PH de pluma portátil PH-108 PH-009II con ATC
Precio: USD1 of PH-108 PH-009II portable Pen PH tester meter with ATC
Detalles de empaquetado: 100 piezas/caja de cartón de PH-108 PH-009II medidor de prueba de PH de pluma portátil con ATC
Tiempo de entrega: 10 días de medidor de prueba de PH de pluma portátil PH-108 PH-009II con ATC
Condiciones de pago: TT de PH-108 PH-009II medidor de prueba de PH de pluma portátil con ATC
Capacidad de la fuente: 5000000 Uds de PH-108 PH-009II medidor de prueba de PH de pluma portátil con ATC
Contacto
Descripción detallada del producto

PH-108 PH-009II portable Pen PH tester meter with ATC

Specification:

Range 0.0 to 14.0 pH

Resolution 0.1 pH

Accuracy ±0.1 pH (at20°C)

Calibration manual, 1 point

Environment RH 95% max;

0 to 50°C (32 to 122°F)

Batteries:  4x 1.5V alkaline

Life approx. 200 hours of use

Dimensions 152x30x21 mm

Weight 50 g

 

PH-108 PH-009II portable Pen PH tester meter with ATC 0

PH-108 PH-009II portable Pen PH tester meter with ATC 1

 

OPERATION

• Remove the protective cap. Do not be alarmed if white crystals appear around the cap. This is normal with pH electrodes and they dissolve when rinsed with water.

• Turn the meter on sliding the switch on the top.

• Immerse into solution up to the max immersion level.

• Stir gently and wait until the display stabilizes.

• After use, switch off pH meter, use the water clean the electrode and replace the protective cap.

DO NOT USE DISTILLED OR DEIONIZED WATER FOR STORAGE PURPOSES.

• Large fluctuations in readings could be due to lack of calibration, dry electrode or rundown batteries.

PH-108 PH-009II portable Pen PH tester meter with ATC 2

 

HANNA HI98107 pHep PEN PH meter PH tester

CALIBRATION

• Immerse the tester up to the maximum immersion level in pH 6.86 buffer solution

• Allow the reading to stabilize and using a small screwdriver adjust the calibration trimmer to read 6.86

Calibration is now complete.

ALWAYS USE FRESH BUFFERS FOR CALIBRATION.

 

BATTERY REPLACEMENT

When the meter cannot be switched on or the display fades, pull out the battery compartment and replace all three 1.5V batteries, while paying attention to their polarity. Batteries should only be replaced in a safe area using the battery type specified in this instruction manual.

PH-108 PH-009II portable Pen PH tester meter with ATC 3

WARRANTY

These instruments are warranted from all defects in material and manufacturing for a period of one year from the date of purchase.

If during this period, the repair or the replacement of parts is required where the damage is not due to negligence or erroneous operation by user, please return the parts to either dealer or our offices, and the repair will be effected free of charge.

PH-108 PH-009II portable Pen PH tester meter with ATC 4

PH-108 PH-009II portable Pen PH tester meter with ATC 5

Contacto
Please input your companyname!
Envíe su pregunta directamente a nosotros (0 / 3000)

Otros productos
Solicitar una cotización

| Mapa del Sitio

Política de privacidad | China Pen PH meter, ORP meter, TDS meter, Conductivity meter Proveedor. Copyright © 2026 Please input your companyname!. All Rights Reserved. Developed by ECER